Yokogawa Power Supply PW402
Complete Collection of New + USED Industrial Products — Automation & Instrumentation | From Field to Factory Floor
Our Services: ✅ Free Global Shipping ✅ 30-Day Returns & Exchanges ✅ Physical Product Photography ✅ Most Favorable Prices
Who We Stock: Our inventory spans the full spectrum of automation infrastructure — from field instrumentation to high-level control systems — sourced from the industry’s leading manufacturers:
🛠️ Process & Discrete Automation: Emerson · Honeywell · Siemens · GE · ABB · Schneider Electric · Rockwell Automation · Mitsubishi Electric · Yokogawa Electric · Fuji Electric
🤖 Robotics & Motion Control: FANUC · Yaskawa (Motoman) · Omron · Keyence · Beckhoff · Lenze · Nidec
⚙️ Fluid Control & Pneumatics: Parker Hannifin · Eaton · Festo · SMC
🔌 Connectivity & Sensing: TE Connectivity · SICK · ifm electronic · TURCK · Pilz
🏭 Industrial Infrastructure & Power: Rittal · Danaher · and more
Product Scope: Field instrumentation → Control systems → Drives & motion → Pneumatics & fluid control → Sensors & connectivity → Power & enclosure infrastructure
📞 Contact Us — WhatsApp: +86 15502977793 · For inquiries, pricing, or availability, reach out anytime.
Yokogawa
Description
Yokogawa PW402 is a high-power single-channel output power module for the Yokogawa CENTUM CS / CENTUM VP DCS system, specifically designed for high-load control stations, supporting wide voltage input and fan cooling.
I. Model and Positioning
Model: PW402 (common suffix S2, hardware version 2)
Series: Standard DCS power supply for CENTUM CS / CENTUM VP
Core Positioning: 5.1V/20A high current single-channel output, providing stable power supply for CPU, communication, and high-density I/O
Different from the PW48x series: PW402 has a single 5.1V output; PW481/PW482 have a 5V + 24V dual-output
II. Key Electrical Parameters (New Original Equipment)
Table
Parameter Item Specification
Input 100–240 VAC, 50/60 Hz (wide voltage adaptive)
Output 5.1 VDC / 20 A (single path)
Total Power 102 W (5.1V × 20A)
Efficiency >85% (full load)
Cooling Fan forced air cooling (heat dissipation for high load)
Protection Overvoltage, Overcurrent, Short Circuit, Undervoltage, Overheat Protection
Isolation Input – Output 1500 VDC Isolation
Redundancy Supports 1+1 Redundancy (paired with PW401/PW404 of the same specification)
Hot Swap Supports (live replacement, without affecting system operation)
III. Physical and Installation
Size: Approximately 51 (W) × 229 (H) × 203 (D) mm
Weight: Approximately 2.0 kg
Installation: Standard DCS Rack Installation (not DIN rail)
Operating Environment: 0–50°C; 5–95% RH (no condensation)
Fuse: 6.3A slow-melting fuse for 220–240V AC input






![Yokogawa paper recorder, model SR10001-2[USED]](https://mlidoo.com/wp-content/uploads/2026/02/5-1-300x300.jpg)
![YOKOGAWA's paper recorder SR10006-3[USED]](https://mlidoo.com/wp-content/uploads/2026/02/30-300x300.jpg)
![YOKOGAWA paperless recorder DX2004-3-4-3[USED]](https://mlidoo.com/wp-content/uploads/2026/02/32-300x300.jpg)
![YOKOGAWA Japanese Yokogawa paperless recorder FX106-4-1[USED]](https://mlidoo.com/wp-content/uploads/2026/02/26-300x300.jpg)