Yokogawa 701260 high-voltage insulation module, 100 ks/s 16-bit isolated module[USED]

$500.00
Yokogawa 701260 high-voltage insulation module, 100 ks/s 16-bit isolated module[USED]

Yokogawa 701260 high-voltage insulation module, 100 ks/s 16-bit isolated module[USED]

$500.00

Description

Yokogawa 701260 High-Voltage 100 kS/s, 16-bit Isolation Module (with RMS measurement), a discontinued plug-in input module for Yokogawa DL850/DL750 ScopeCorders, replaced by 701267 (and later 720268) after safety standard non-compliance in late 2013, with final discontinuation on Dec 31, 2013.

Core Specifications

表格
Parameter Details
Model 701260
Channels 2 fully isolated unbalanced channels
Sampling Rate 100 kS/s (max per channel)
A/D Resolution 16 bits
Input Coupling AC, DC, GND, AC‑RMS, DC‑RMS
Input Ranges (1:1 probe) 20 mV/div to 200 V/div (1‑2‑5 steps); max input (DC+AC peak) 850 V
Input Ranges (10:1 probe) 200 mV/div to 2000 V/div; max input (DC+AC peak) 8500 V
Frequency Response (‑3 dB) Waveform mode: DC to 40 kHz; RMS mode: 40 Hz to 10 kHz
DC Accuracy ±0.25% of full scale (after 30‑min warm‑up, calibrated)
Isolation Channel‑to‑channel & channel‑to‑ground isolation for high‑noise industrial environments
DC Offset ±5 div
Front Connector BNC (compatible with safety probes 7019xx series)
Operating Temp 0°C to +40°C

Key Features

  1. Dual isolated high‑voltage input: prevents ground loops and ensures safety in power electronics testing (inverters, motor drives, switchgear).
  2. Built‑in RMS computation: real‑time AC/DC RMS readings without external math processing.
  3. 16‑bit precision at 100 kS/s: balances speed and resolution for medium‑speed high‑voltage transient capture.
  4. Anti‑aliasing filter matched to the 100 kS/s rate to avoid frequency aliasing.
  5. Hot‑swappable in compatible ScopeCorder chassis for minimal downtime during test setup changes.

Typical Applications

  • High‑voltage power converter waveform analysis
  • Industrial motor drive voltage monitoring
  • Transformer and power supply transient testing
  • Power quality (RMS voltage/current) logging
  • High‑noise plant floor electrical measurements requiring galvanic isolation