
Yokogawa YS1360 Programmable Indicator Controller
$720.00
Description
Description
Yokogawa YS1360 – Manual Operation Station (Programmable Indicator/Controller)
YS1360 is Yokogawa’s manual operation station (manual setter for MV) in the YS1000 series, designed for manual output of operation signals to final control elements (valves, actuators)Yokogawa. It replaces the legacy YS136 and is widely used in process industries for local/remote manual override.
Core Identity
- Full Name: YS1360 Manual Operation Station (Programmable Indicator/Controller)
- Series: YS1000 Single‑Loop Controllers
- Primary Role: Manual output of MV (Manipulated Variable) signals to operation terminals
- Key Feature: Cascade (C) / Manual (M) mode switching (standard)
- Display: 120×320 dot color semi‑reflective LCD (meter, trend, bar, alarm, event views)
- Memory: Non‑volatile (no battery/capacitor backup; maintenance‑free)
Key Specifications
1. Power Supply
- Standard: 100 VAC / 24 VDC (code 0)
- Option: 220 VAC (code 1)
- 220–240 VDC: Must be specified at order
2. Physical & Environmental
- Panel Cut: DIN short case (96×96 mm)
- Depth: 250 mm (basic type)
- Front Panel: IP54 (dust‑proof, splash‑proof)
- Operating Temp: 0–55°C
- Humidity: 5–95% RH (non‑condensing)
- Certifications: CE, FM (optional explosion‑proof)
3. I/O & Communication
- Output: Analog MV (4–20 mA DC, configurable)
- Inputs: Status inputs for mode selection
- Outputs: Mode status (C/M)
- Communication Options:
- RS‑485 (Modbus RTU)
- Ethernet (Modbus/TCP, basic type only)Yokogawa
- DCS‑LCS link (for Yokogawa CENTUM integration)
4. Front Panel Controls (YS1360)
- Color LCD (120×320)
- FAIL (red LED)
- ALM (yellow LED)
- C (green) / M (yellow) mode keys
- MV ↓ key
- MV ↑ key
- Page key
- Fast‑change / SHIFT key
Main Functions
- Manual Operation: Directly adjust MV output via front‑panel keys; hard‑manual backup circuit inside.
- Mode Switching:
- C (Cascade): Follows remote setpoint from primary controller
- M (Manual): Local manual adjustment of MV
- Display Flexibility: Meter, trend, bar graph, alarm, and event displaysYokogawa.
- Parameter Setup:
- Front‑panel configuration (no need to remove internal unit)
- PC setup via YSS1000 software
- Output Balance: Smooth bumpless transfer between C and M modes.
- Diagnostics: Self‑diagnosis with FAIL/ALM indicators.









![YOKOGAWA paper recorder SR1006-B-1[USED]](https://mlidoo.com/wp-content/uploads/2026/02/14-1-300x300.jpg)
![Yokogawa recorder SR10006-2 6-channel paper-based recorder[USED]](https://mlidoo.com/wp-content/uploads/2026/02/2-1-300x300.jpg)
![YOKOGAWA FX1004-4-3-L paperless recorder with USB1 interface[USED]](https://mlidoo.com/wp-content/uploads/2026/02/7-300x300.jpg)
![YOKOGAWA Japanese Yokogawa paperless recorder FX112-4-2[USED]](https://mlidoo.com/wp-content/uploads/2026/02/13-300x300.jpg)