Cognex CIO-1400 Camera Module

$300.00
Cognex CIO-1400 Camera Module

Cognex CIO-1400 Camera Module

$300.00

Description

Cognex CIO‑1400 Discrete I/O Expansion Module

The CIO‑1400 (P/N: 800‑9012‑2R) is a DIN‑rail mountable discrete I/O expansion module for select Cognex In‑Sight vision systems, providing consolidated access to trigger, power, serial (RS‑232), and high‑speed I/O, plus extended general‑purpose I/O for machine integrationCognex. It is not a camera module but a critical peripheral for In‑Sight cameras.

Core Identity

表格
Parameter Value
Model CIO‑1400 (In‑Sight 1400 I/O Expansion Module)
Part Number 800‑9012‑2R
Type Discrete I/O Expansion Module (Trigger, Power, RS‑232, High‑Speed I/O)
Mounting DIN‑rail (35 mm)
Housing Plastic
Dimensions 130 (W) × 46.6 (H) × 89.6 (D) mm
Weight ~0.3 kg

Compatibility

Supported In‑Sight vision systems (official Cognex list)CognexCognex:
  • In‑Sight 5000 Series (excluding 5604)
  • In‑Sight 7000 Gen2 Series
  • In‑Sight 9000 Series
  • Legacy support: In‑Sight 3400 SeriesCognex
Note: Not compatible with In‑Sight Micro 1000 Series (use CIO‑MICRO instead)CognexCognex.

Key I/O Specifications

Inputs

  • 1 × Isolated Trigger Input (TRIGGER +/–): Opto‑isolated (sensor‑side), 20–28 V DC sink/source
  • 7 × General‑Purpose Inputs: Opto‑isolated, 24 V DC nominal, sink/source configurableCognexCognex

Outputs

  • 2 × High‑Speed Outputs: Configurable as NPN (sinking), 50 mA max per channelCognex
  • 6 × General‑Purpose Outputs: Configurable as NPN/PNP (sinking/sourcing), 100 mA max per channel (30 V DC max)Cognex

Communication & Power

  • RS‑232 Port: DB9 male (RS232 OUT) for serial devices (handshaking supported)CognexCognex
  • Power Input: 24 V DC (from vision system or external)
  • Connection: Dedicated I/O cable (DB15 to M12) – sold separatelyCognex

Status Indicators

  • MODULE OK, COMM OK (data transmission)
  • Individual LEDs for Trigger, each Input, and each Output (yellow)CognexCognex

Critical Notes

  1. Software Requirement: In‑Sight Explorer 6.3.0 or higher; configurations are not retained in older versionsCognexCognex.
  2. Cable: Requires a Cognex I/O cable (DB15 to M12) to connect to the vision sensor’s SENSOR portCognexCognex.
  3. Replacement: Replaces the legacy CIO‑1450 module.